Network Reports (ACPFlowReport)

buildACPFlowReport returns a machine-readable report object next to the formatted terminal output of printACPFlowResults.

Build a report

using Sparlectra

net = Net(name = "report_demo", baseMVA = 100.0)

addBus!(net = net, busName = "B1", vn_kV = 110.0)
addBus!(net = net, busName = "B2", vn_kV = 110.0)
addBus!(net = net, busName = "B3", vn_kV = 110.0)
addBus!(net = net, busName = "B4", vn_kV = 110.0)

# line totals in ohm and siemens, or values per km and the length
addACLine!(net = net, fromBus = "B1", toBus = "B2", r_ohm = 0.6, x_ohm = 1.95, b_s = 1.5e-5, length_km = 5.0)
addACLinePerKm!(net = net, fromBus = "B3", toBus = "B4", length_km = 20.0, r_ohm_per_km = 0.12, x_ohm_per_km = 0.39, c_nf_per_km = 9.5)

# Optional bus-link connection (reported in report.links)
addLink!(net = net, fromBus = "B2", toBus = "B3", status = 1)

addProsumer!(net = net, busName = "B1", type = "EXTERNALNETWORKINJECTION", referencePri = "B1")
addProsumer!(net = net, busName = "B2", type = "GENERATOR", p = 10.0, q = 1.0)
addProsumer!(net = net, busName = "B3", type = "ENERGYCONSUMER", p = 15.0, q = 5.0)
addProsumer!(net = net, busName = "B4", type = "ENERGYCONSUMER", p = 25.0, q = 10.0)

cfg = SparlectraConfig(powerflow = PowerFlowConfig(max_iter = 40, tol = 1e-10))
result = run_sparlectra(net = net, config = cfg)
ite, etime = result.iterations, result.elapsed_s

report = buildACPFlowReport(
  net;
  ct = etime,
  ite = ite,
  tol = 1e-10,
  converged = result.final_converged,
  solver = :rectangular,
)

The snippet is a complete script for a julia --project=. session.

Report content

ACPFlowReport has the fields metadata, nodes, branches, links, transformer_controls, q_limit_events and hvdc_links:

report.metadata.total_p_loss_MW
report.nodes[1]
report.branches[1]
report.links

DataFrame conversion

Each vector field converts directly:

using DataFrames

nodes_df = DataFrame(report.nodes)
branches_df = DataFrame(report.branches)
links_df = DataFrame(report.links)